Quote list0
HP30 air-operated diaphragm pump, assembled Illustrative image: HP30 metal body. Dimensions and body color vary by model.
Air-operated diaphragmCE

HP200

High pressure · Aluminium. For lines that need 140 m of head.

Flow
200l/dk
Connection
2inch
Discharge head
140m
Solids passage
6mm
Size
Body
Valve type

Ball valve: for viscous fluids and small solids.

Configuration codeHP200-AL-NE-BThe code structure is for the prototype only; the final coding will be matched to the catalog.

Price and lead time are in the quote. If you tell us your fluid, our engineer will check the elastomer selection.

Technical specifications

Body materialAluminium
Flow (maximum)200 l/dk
Inlet – outlet2″
Operating pressure (maximum)7 bar
Discharge head (maximum)140 m
Suction lift6 m
Operating temperature−18 … +100 °C
Air inlet¾″
Solids passage6 mm
Weight34,0 kg
Elastomer optionsNeoprene, Buna-N, EPDM, Viton, Santoprene, Teflon
Connection typeThreaded / flanged

Compare within the series

Other sizes in the same body. Click a row to switch the page to that model.

ModelFlow (l/dk)ConnectionWeight (kg)
HP100701″10,0
HP1501601½″27,0
HP2002002″34,0
HP3003603″55,0

Performance

The catalog curves give the flow–head relationship according to the air inlet pressure and air consumption. In this prototype only the catalog end values are marked; intermediate curves will be added with test data.

  • 200 l/dkMaximum flow in free discharge
  • 7 barMaximum operating pressure at the air inlet
  • 6 mDry suction lift
HP200 flow and discharge head end values0448813217622004081121161Flow (l/dk)Head (m)140 m200 l/dk
The dashed line joins the end points; it is not an actual curve.

Working principle

Two diaphragms are connected to each other by a common shaft. The air valve directs compressed air alternately into the diaphragm chambers; while one diaphragm pushes the fluid, the other one draws suction. The valve changes direction at the end of the stroke.

Animated explanation
  • Dry-run resistantNo heating or wear occurs when the line runs empty.
  • Safe stop against back pressureStops when the discharge line is closed and resumes pumping when it is opened.
  • Suitable for explosive atmospheresContains no electric motor and no electrical connection.
  • Simple constructionContains no mechanical seal, rotor or impeller; maintenance needs are low.

Documents

HP200 high pressure, Neoprene, ball valve

Contact us for quotes and technical support.

Quote formContact details